Acoustic Phase Interference

 

Multiple Microphones

Acoustic phase interference occurs when the same sound arrives at two or more adjacent microphones at different times. This happens, for example, when two microphones are placed on a lectern as in Fig. 16. Because they are spaced apart, sound from the subject will almost certainly arrive at the two microphones at different times. The curves in Fig. 17 show the effects of the destructive wave interferences this causes when the microphone outputs are mixed together. These response degradations can result in not only poor audio quality, but often feedback problems as well.

 

Figure 16: Unequal Microphone Distances

 

 

 

 

 

 

 

Figure 17: Multiple Microphone Response Curves

 

 

An obvious solution to this lectern-mic problem would be to use only one microphone. This not only improves the sound quality, but cuts the lectern microphone budget by approximately 50%! (Sometimes a second microphone may be desired as part of a backup or “redundancy” system, such as for press conferences. The two microphones should then be located directly in front of the subject, as close together as practical, and only one should be on or “open” at a time.)

Fig. 18 shows another approach to podium miking with two microphones. Here the two mics are placed with their capsules as close together as possible, and angled in a “crossfire.” This provides a wider overall acceptance angle, allows stereo miking with excellent mono compatibility, and largely avoids the phase interference problem.

 

Figure 18: Multi-mic Podium Setup

 

 

 

 

 

 

 

Figure 19: The 3:1 Ratio Rule

 

 

Whenever two spaced microphones must be used, the “3:1 Ratio Rule” is a good guide for placement. Fig. 19 illustrates this rule of thumb. In the illustration, Microphone 1 is one foot from the sound source. The next closest microphone in the system, Microphone 2, should be located three feet or more from Microphone 1. If the distance between the sound source and Microphone 1 changes to two feet, then the minimum distance between the two microphones should be at least six feet, maintaining the 3:1 ratio.

Single Microphone Placement

Acoustic phase interference may also occur when only a single microphone is in use. This happens when sound is reflected off a nearby surface and arrives at the microphone slightly after the direct sound. Adding the two signals together may give problems similar to those encountered in improper multi-microphone setups. (The phase interference will be most noticeable when the reflected sound arrives at a sound pressure level that is within 9 dB of the direct sound.)

There are several ways to eliminate this problem. First, try putting the microphone closer to the sound source. Second, move the microphone farther from the reflective surface. Third, use a microphone specially configured to be placed extremely close to the reflective plane (Fig. 20). When using a low profile directional Audio-Technica boundary or “plate” microphone, for example, the microphone capsule is so close to the surface that the direct sound and the reflected sound arrive simultaneously and add together rather than cancel. This technique can prove very helpful on the apron of a stage, on a table or desk for conference use, or on the altar of a church.

 

Figure 20: Effects of Reflections

 

 

 

Current Location English / $ CAD

Change your location

United States

United States

Europe

Albania
Andorra
Armenia
Azerbaijan
Bosnia & Herzegovina
Georgia
Iceland
United Kingdom
Germany
France
Netherlands
Spain
Hungary
Austria
Bulgaria
Croatia
Cyprus
Czechia
Denmark
Estonia
Finland
Greece
Ireland
Italy
Latvia
Lithuania
Luxembourg
Malta
Poland
Portugal
Romania
Slovakia
Slovenia
Sweden
Ukraine
Turkey
Switzerland
Serbia
San Marino
Norway
North Macedonia
Montenegro
Monaco
Liechtenstein
Kazakhstan

Canada

Latin America

Argentina
Bolivia
Brazil
Chile
Colombia
Costa Rica
Cuba
Dominican Republic
Ecuador
El Salvador
Guatemala
Haiti
Honduras
Mexico
Nicaragua
Panama
Paraguay
Peru
Uruguay
Venezuela

Africa

Algeria
Angola
Benin
Botswana
Burkina Faso
Burundi
Cameroon
Cape Verde
Central African Republic
Chad
Comoros
DR Congo
Congo Republic
Djibouti
Egypt
Equatorial Guinea
Eritrea
Eswatini
Ethiopia
Gabon
Gambia
Ghana
Guinea
Guinea-Bissau
Ivory Coast
Kenya
Lesotho
Liberia
Libya
Madagascar
Malawi
Mali
Mauritania
Mauritius
Morocco
Mozambique
Namibia
Nigeria
Rwanda
Sao Tome and Principe
Senegal
Seychelles
Sierra Leone
Somalia
South Africa
Sudan
Tanzania
Togo
Tunisia
Uganda
Zambia
Zimbabwe

Asia

Vietnam
Yemen
Afghanistan
Bahrain
Bangladesh
Bhutan
Brunei
Cambodia
China
Hong Kong
India
Indonesia
Iran
Iraq
Israel
Japan
Jordan
Kuwait
Kyrgyzstan
Laos
Lebanon
Macao
Malaysia
Maldives
Mongolia
Myanmar
Nepal
Oman
Pakistan
Philippines
Qatar
Saudi Arabia
Singapore
South Korea
Sri Lanka
Syria
Taiwan
Tajikistan
Thailand
Timor-Leste
Turkmenistan
United Arab Emirates
Uzbekistan
Vietnam
Yemen

Oceania

Australia
Fiji
Kiribati
Marshall Islands
Micronesia
Nauru
New Zealand
Palau
Papua New Guinea
Samoa
Solomon Islands
Tonga
Tuvalu
Vanuatu
Moldova