Audio Solutions Question of the Week: How Do I Align the Cartridge on the AT-LP120-USB and AT-LP1240-USB Turntables?

Question: How do I align the cartridge on the AT-LP120-USB and AT-LP1240-USB turntables?

Answer: Proper alignment of a turntable’s stylus (needle) is needed in order to realize the full potential of the turntable cartridge and stylus system. Proper alignment of the stylus as it relates to the record groove insures the most accurate reproduction of the recording and the least amount of wear on the record and the stylus. Various tools are available for achieving this alignment.

AT-LP120-USB

Stylus Overhang

At the very least, the specified stylus overhang (the distance the stylus tip extends beyond the center spindle when the headshell is positioned directly above the spindle) should be set. A simple way to set overhang is to use an overhang gauge that has markings in millimeters (mm). Common stylus overhang distances are 15 mm (as is the case for our AT-LP1240-USB turntable) and 16 mm (for our AT-LP120-USB turntable), but other lengths exist as well. Note that on a turntable that includes a premounted cartridge/stylus the overhang has typically been preset at the factory.

Tangency

To insure the most accurate reproduction of the recording, low noise and least amount of wear on the record and stylus, it is important that the stylus be aligned in such a way that its tip remains as tangent to the record groove as possible as it travels across the record. With a pivoted tonearm, it is possible to achieve perfect tangency at only two points as the tonearm travels in an arc across the record. These two points are known as null points (points where there is no tracking error). A two-point cartridge alignment protractor can help achieve this tangency. You can download and print a two-point protractor below – just be sure to print the protractor to actual size.

The two-point protractor has a dot for the stylus tip to rest on and a grid to which the stylus cantilever (the tube that extends from the cartridge body and has the stylus attached to it) aligns. If the stylus cantilever is not easily seen, align the sides of the cartridge body to the lines on the grid instead. In this case, we are assuming that the cantilever is centered and straight as it relates to the sides of the cartridge. Like all two-point protractors, ours has an outer dot/grid and an inner dot/grid. If you choose to use a different protractor, it is important to select one that is suitable for the effective length of the tonearm on your turntable. For the AT-LP120-USB turntable, the effective length is 230.5 mm. For the AT-LP1240-USB turntable, the effective length is 230 mm. The protractor on our website is suitable for both of these turntables.

With the mounting hardware loose enough to allow forward and backward movement of the cartridge in the headshell, position the cartridge to allow the stylus tip to rest on the protractor’s outer dot (the dot farthest from the center spindle). This will set the correct stylus overhang. Next, align the stylus cantilever to the lines on the grid. If the cantilever is not easily seen, align the sides of the cartridge body to the lines on the grid instead. Provided the stylus tip has been attached properly during manufacturing, the tip will be tangent to the record groove when the cantilever is aligned to the grid. Note that you may need to twist the cartridge slightly in the headshell (when looking down on it from above) to achieve the best alignment to the grid. When done, the cartridge may not necessarily end up being parallel to the headshell.

Once you’ve aligned the cartridge to the outer dot/grid, move the tonearm to the inner dot/grid to double-check that the cartridge and stylus align there as well. They should align to the inner dot/grid without further adjustment. If they don’t, recheck that the stylus overhang has been set correctly, that the headshell is properly attached to the tonearm, and that the stylus is properly attached to the cartridge. Make any necessary adjustments, then recheck the alignment against both the outer and inner dots/grids. Once aligned, tighten the mounting hardware until snug.

If you need additional assistance with aligning your cartridge, please contact our Audio Solutions Department.

Current Location English / $ USD

Change your location

United States

United States

Europe

Albania
Andorra
Armenia
Azerbaijan
Bosnia & Herzegovina
Georgia
Iceland
United Kingdom
Germany
France
Netherlands
Spain
Hungary
Austria
Bulgaria
Croatia
Cyprus
Czechia
Denmark
Estonia
Finland
Greece
Ireland
Italy
Latvia
Lithuania
Luxembourg
Malta
Poland
Portugal
Romania
Slovakia
Slovenia
Sweden
Ukraine
Turkey
Switzerland
Serbia
San Marino
Norway
North Macedonia
Montenegro
Monaco
Liechtenstein
Kazakhstan

Canada

Latin America

Argentina
Bolivia
Brazil
Chile
Colombia
Costa Rica
Cuba
Dominican Republic
Ecuador
El Salvador
Guatemala
Haiti
Honduras
Mexico
Nicaragua
Panama
Paraguay
Peru
Uruguay
Venezuela

Africa

Algeria
Angola
Benin
Botswana
Burkina Faso
Cameroon
Cape Verde
Central African Republic
Comoros
DR Congo
Congo Republic
Djibouti
Egypt
Equatorial Guinea
Eritrea
Eswatini
Ethiopia
Gabon
Gambia
Ghana
Guinea
Guinea-Bissau
Ivory Coast
Kenya
Lesotho
Liberia
Libya
Madagascar
Malawi
Mauritania
Mauritius
Morocco
Mozambique
Namibia
Nigeria
Rwanda
Sao Tome and Principe
Senegal
Seychelles
Sierra Leone
Somalia
South Africa
Sudan
Tanzania
Tunisia
Uganda
Zambia
Zimbabwe

Asia

Vietnam
Yemen
Afghanistan
Bahrain
Bangladesh
Bhutan
Brunei
Cambodia
China
Hong Kong
India
Indonesia
Iran
Iraq
Israel
Japan
Jordan
Kuwait
Kyrgyzstan
Laos
Lebanon
Macao
Malaysia
Maldives
Mongolia
Myanmar
Nepal
Oman
Pakistan
Philippines
Qatar
Saudi Arabia
Singapore
South Korea
Sri Lanka
Syria
Taiwan, Province of China
Tajikistan
Thailand
Timor-Leste
Turkmenistan
United Arab Emirates
Uzbekistan
Vietnam
Yemen

Oceania

Australia
Fiji
Kiribati
Marshall Islands
Micronesia
Nauru
New Zealand
Palau
Papua New Guinea
Samoa
Solomon Islands
Tonga
Tuvalu
Vanuatu
Moldova