Question: How do I update the 5000 Series 3rd generation transmitters to firmware v1.05.00?

Answer: Along with updating the firmware on your Audio-Technica receivers, it is just as important to do the same for the transmitters. Last week we updated the firmware on the 5000 Series receivers, and below are detailed instructions for updating the ATW-T5201 body-pack transmitters and ATW-T5202 handheld transmitters. Firmware v1.05.00 adds two additional features from the previous update. First, the transmitter will now retain the “Mute” and “RF Off” settings when the power is cycled. The other new feature is that the transmitter will now show the last screen displayed prior to being powered off. The update may be done on a Windows computer with OS 7 or higher. The updating process is detailed below.

  1. Download the firmware update ZIP file from the Audio-Technica website or the following links:

ATW-T5201 Body-Pack

https://www.audio-technica.com/media/wysiwyg/product/pdfs/us/atw_t5201_de1_ef2.zip

ATW-T5202 Handheld

https://www.audio-technica.com/media/wysiwyg/product/pdfs/us/atw_t5202_de1_ef2.zip

Included in the ZIP file is the application to transfer the update as well as instructions in PDF form.

  1. Be certain the computer and receiver have the same network settings. Attach your firmware-updated ATW-R5220 or ATW-R5220DAN receiver to the Windows computer with a standard Cat5 cable. Power on the computer and receiver.
  2. Launch the Update Application “ATW-T5201-DE1-EG1-EF2_001.005.000” or “ATW-T5202-DE1-EG1-EF2_001.005.000.” Select NEXT to begin.Audio Solutions Question of the Week: How Do I Update the 5000 Series 3rd Generation Transmitters to Firmware v1.05.00?
  3. Select your desired transmitter: “BP” for the ATW-T5201 or “HH” for the ATW-T5202. To identify your connected receiver, click the circle button to the left of the receiver, which will blink the OLED display of the corresponding hardware. Select NEXT.Audio Solutions Question of the Week: How Do I Update the 5000 Series 3rd Generation Transmitters to Firmware v1.05.00?
  4. Note the update progress. Do NOT disconnect the power or power down while updating.Audio Solutions Question of the Week: How Do I Update the 5000 Series 3rd Generation Transmitters to Firmware v1.05.00?
  5. When the following pop-up screen appears, click OK.Audio Solutions Question of the Week: How Do I Update the 5000 Series 3rd Generation Transmitters to Firmware v1.05.00?
  6. Next, open up your transmitter battery compartment to access the buttons. Press and hold the SET and SYNC buttons simultaneously while powering on the transmitter. Continue to hold until the display indicates “BOOT MODE,” at which time you may release the buttons.Audio Solutions Question of the Week: How Do I Update the 5000 Series 3rd Generation Transmitters to Firmware v1.05.00?
  7. Place your transmitter’s IR SYNC window next to the receiver’s IR SYNC window.Audio Solutions Question of the Week: How Do I Update the 5000 Series 3rd Generation Transmitters to Firmware v1.05.00? Audio Solutions Question of the Week: How Do I Update the 5000 Series 3rd Generation Transmitters to Firmware v1.05.00?
  8. Hold there in place while the receiver transfers the firmware update to the transmitter.
  9. When the update is successfully completed, the confirmation screen will show on the computer. Click CLOSE to finish.Audio Solutions Question of the Week: How Do I Update the 5000 Series 3rd Generation Transmitters to Firmware v1.05.00?

If the power is disrupted while updating the firmware, or the IR SYNC failed, you may repeat steps #7 – #10 above.

Once you have completed the firmware updates, turn the transmitters and receivers off and then back on to ensure the firmware update has completed properly. If you have any questions with the update process, please contact the Audio Solutions Department.

Current Location English / $ USD

Change your location

United States

United States

Europe

Albania
Andorra
Armenia
Azerbaijan
Bosnia & Herzegovina
Georgia
Iceland
United Kingdom
Germany
France
Netherlands
Spain
Hungary
Austria
Bulgaria
Croatia
Cyprus
Czechia
Denmark
Estonia
Finland
Greece
Ireland
Italy
Latvia
Lithuania
Luxembourg
Malta
Poland
Portugal
Romania
Slovakia
Slovenia
Sweden
Ukraine
Turkey
Switzerland
Serbia
San Marino
Norway
North Macedonia
Montenegro
Monaco
Liechtenstein
Kazakhstan

Canada

Latin America

Argentina
Bolivia
Brazil
Chile
Colombia
Costa Rica
Cuba
Dominican Republic
Ecuador
El Salvador
Guatemala
Haiti
Honduras
Mexico
Nicaragua
Panama
Paraguay
Peru
Uruguay
Venezuela

Africa

Algeria
Angola
Benin
Botswana
Burkina Faso
Burundi
Cameroon
Cape Verde
Central African Republic
Chad
Comoros
DR Congo
Congo Republic
Djibouti
Egypt
Equatorial Guinea
Eritrea
Eswatini
Ethiopia
Gabon
Gambia
Ghana
Guinea
Guinea-Bissau
Ivory Coast
Kenya
Lesotho
Liberia
Libya
Madagascar
Malawi
Mali
Mauritania
Mauritius
Morocco
Mozambique
Namibia
Nigeria
Rwanda
Sao Tome and Principe
Senegal
Seychelles
Sierra Leone
Somalia
South Africa
Sudan
Tanzania
Togo
Tunisia
Uganda
Zambia
Zimbabwe

Asia

Vietnam
Yemen
Afghanistan
Bahrain
Bangladesh
Bhutan
Brunei
Cambodia
China
Hong Kong
India
Indonesia
Iran
Iraq
Israel
Japan
Jordan
Kuwait
Kyrgyzstan
Laos
Lebanon
Macao
Malaysia
Maldives
Mongolia
Myanmar
Nepal
Oman
Pakistan
Philippines
Qatar
Saudi Arabia
Singapore
South Korea
Sri Lanka
Syria
Taiwan, Province of China
Tajikistan
Thailand
Timor-Leste
Turkmenistan
United Arab Emirates
Uzbekistan
Vietnam
Yemen

Oceania

Australia
Fiji
Kiribati
Marshall Islands
Micronesia
Nauru
New Zealand
Palau
Papua New Guinea
Samoa
Solomon Islands
Tonga
Tuvalu
Vanuatu
Moldova